[Audio] © Siemens AG 2009 SENTRON Switching and Protection Devices – Molded Case Circuit Breakers 16 16/2 Introduction 3VL Molded Case Circuit Breakers 3VL Molded Case Circuit Breakers up to 1600 A 16/6 General data 16/10 3-pole 16/28 4-pole 16/48 Options 16/50 Accessories and spare parts 3VF2 Molded Case Circuit Breakers 3VF2 Molded Case Circuit Breakers up to 100 A 16/91 3-pole, fixed-mounted versions 16/91 4-pole, fixed-mounted versions 16/92 Accessories and spare parts Siemens LV 1 · 2009.

Scene 2 (2m 36s)

[Audio] © Siemens AG 2009 SENTRON Switching and Protection Devices — Molded Case Circuit Breakers Introduction ■ Overview Type VL160X/3VL1 VL160/3VL2 VL250/3VL3 VL400/3VL4 Molded case circuit breakers 3VL molded case circuit breakers up to 1600 A Rated current In at 50 °C ambient temperature1) A 16 ... 160 50 ... 160 200 ... 250 200 ... 400 Number of poles 3 4 3 4 3 4 3 4 Rated operational voltage Ue AC 50/60 Hz DC2) V V 690 500 690 500 690 600 690 600 690 600 690 600 690 600 690 600 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ---✓ ---Electronic releases Thermal-magnetic Electronic LCD ETU/ETU Replaceable PROFIBUS module COM10/COM20 Dimensions 105 157 139 157 105 175 139 175 105 175 139 175 ���81 81 81 81 81 81 A B C D mm mm mm mm 107 107 107 107 107 107 139 279 102 138 183 279 102 138 � � � � � � � � � � Switching capacity Icu/Ics RMS value acc. to IEC 60947-2 Standard switching capacity N3) N 16 Up to 240 V AC Up to 415 V AC Up to 440 V AC Up to 500/525 V AC Up to 690 V AC kA kA kA kA kA 65/65 55/55 25/20 18/14 8/44) 65/65 55/55 25/20 25/20 12/6 65/65 55/55 25/20 25/20 12/6 65/65 55/55 35/26 25/20 15/8 Up to 250 V DC5) Up to 500 V DC5) Up to 600 V DC5) kA kA kA 30/30 --32/32 --32/32 --32/32 --NEMA breaking capacity6) Up to 480 V AC Up to 600 V AC kA kA 25 84) 25 12 25 12 35 20 High switching capacity H3) H Up to 240 V AC Up to 415 V AC Up to 440 V AC Up to 500/525 V AC Up to 690 V AC kA kA kA kA kA 100/75 70/70 42/32 30/23 12/64) 100/75 70/70 50/38 40/30 12/6 100/75 70/70 50/38 40/30 12/6 100/75 70/70 50/38 40/30 15/8 Up to 250 V DC5) Up to 500 V DC5) Up to 600 V DC5) kA kA kA 30/30 30/30 -32/32 32/32 -32/32 32/32 -32/32 32/32 -NEMA breaking capacity6) Up to 480 V AC Up to 600 V AC kA kA 42 124) 50 12 50 12 50 20 Very high switching capacity L3) L Up to 240 V AC Up to 415 V AC Up to 440 V AC Up to 500/525 V AC Up to 690 V AC kA kA kA kA kA -----200/150 100/75 75/50 50/38 12/6 200/150 100/75 75/50 50/38 12/6 200/150 100/75 75/50 50/38 15/8 Up to 250 V DC5) Up to 500 V DC5) Up to 600 V DC5) kA kA kA ---32/32 32/32 32/32 32/32 32/32 32/32 32/32 32/32 32/32 NEMA breaking capacity6) Up to 480 V AC Up to 600 V AC kA kA --75 12 75 12 75 20 1) 3VF2 at 40 °C ambient temperature. 2) Rated DC voltage applies only for circuit breakers with ✓ Available -- Not available thermal-magnetic release. For 3VL molded case circuit breakers according to UL 489 see Catalog LV 16. 16/2 Siemens LV 1 · 2009.

Scene 3 (4m 26s)

[Audio] © Siemens AG 2009 SENTRON Switching and Protection Devices — Molded Case Circuit Breakers Introduction VL630/3VL5 VL800/3VL6 VL1250/3VL7 VL1600/3VL8 3VF2 3VL molded case circuit breakers up to 1600 A 3VF2 molded case circuit breakers up to 100 A 315 ... 630 800 1000 ... 1250 1600 16 ... 100 3 4 3 4 3 4 3 4 3 and 4 690 600 690 600 690 -690 -690 -690 -690 -690 -Up to 415 --✓ ✓ ✓ -✓ ✓ ✓ -✓ ✓ ✓ -✓ ✓ ✓ -✓ ✓ ✓ -✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ---76/102 124 190 279 102 138 253 279 102 138 190 406 114 151 253 406 114 151 229 406 152 207 305 406 152 207 229 406 152 207 305 406 152 207 68 73 16 65/65 45/45 35/26 25/20 20/10 65/65 50/50 35/26 25/20 20/10 65/35 50/25 35/26 25/20 20/10 65/35 50/25 35/26 25/20 20/10 65/33 18/9 ---32/32 --------------25 20 25 20 25 20 25 20 --100/75 70/70 50/38 40/30 30/15 100/75 70/70 50/38 40/30 30/15 100/50 70/35 50/38 40/30 30/15 100/50 70/35 50/38 40/30 30/15 -----32/32 32/32 -------------50 30 50 30 50 30 50 30 --200/150 100/75 75/50 50/38 20/10 200/150 100/75 75/50 50/38 20/10 200/100 100/50 75/50 50/38 35/17 200/100 100/50 75/50 50/38 35/17 -----32/32 32/32 32/32 ------------65 35 65 35 65 35 65 35 --5) The maximum permitted DC voltage for each conducting path needs to be taken 3) At 240 V AC, 415 V AC and 525 V AC max. 5 % overvoltage, at 440 V AC, 500 V AC and 690 V AC max. 10 % overvoltage, at 250/500/600 V DC max. 5 % overvoltage. into account for DC switching applications, see Technical Information LV 1T, "Configuring", "Switching of DC Currents"; time constant t = 15 ms. 6) The NEMA breaking capacity can be found on the rating plate of each IEC circuit 4) Rated current In ≥ 25 A. breaker. 16/3 Siemens LV 1 · 2009.

Scene 4 (5m 32s)

[Audio] © Siemens AG 2009 SENTRON Switching and Protection Devices — Molded Case Circuit Breakers Introduction 10 10 11 12 13 NSE0_01959a 16 $ Withdrawable/plug-in bases (pages 16/62 to 16/67) % Side walls for withdrawable version (pages 16/62 to 16/67) & Phase barriers (pages 16/69 to 16/74) ( Flared front busbar connecting bars (pages 16/69 to 16/74) ) Straight connecting bars (pages 16/69 to 16/74) * Circular conductor terminal for Al/Cu (pages 16/72 to 16/74) + Box terminals for Cu (pages 16/69 to 16/74) , Extended terminal covers (pages 16/69 to 16/74) - Standard terminal covers (pages 16/69 to 16/74) . Masking frames/cover frames for door cut-out (pages 16/86 to 16/89) / Motorized operating mechanisms with spring energy store (pages 16/56 to 16/57) 0 Front-operated rotary operating mechanisms (pages 16/53 to 16/58) 1 Door-coupling rotary operating mechanisms (pages 16/53 to 16/58) 2 SENTRON 3VL circuit breakers (pages 16/10 to 16/49) 3 Internal accessories (pages 16/48, 16/50 to 16/51) 4 Electronic releases LCD ETU (pages 16/12 to 16/21, 16/25 to 16/27, 16/34 to 16/41, 16/45 to 16/47) 5 Electronic releases with communication function (pages 16/14 and 16/15, 16/18 and 16/19, 16/26, 16/38 and 16/39, 16/46) 6 Thermal-magnetic overcurrent releases (pages 16/10 to 16/17, 16/24, 16/28 to 16/37, 16/44) 7 RCD modules (page 16/68) 8 Rear terminals – flat and round (pages 16/69 to 16/74) 9 COM10 communication modules to the PROFIBUS DP (page 16/90) : COM20 communication modules to the PROFIBUS DP (page 16/90) ; Battery power supplies with test function for electronic releases (pages 16/76 to 16/80) 16/4 Siemens LV 1 · 2009.

Scene 5 (6m 56s)

[Audio] © Siemens AG 2009 SENTRON Switching and Protection Devices — Molded Case Circuit Breakers Introduction 9 8 7 2 6 5 3 4 1 15 14 18 23 16 16 19 17 21 7 22 6 5 NSE0_01960b 9 4 8 20 3 16/5 Siemens LV 1 · 2009.

Scene 6 (7m 58s)

[Audio] © Siemens AG 2009 3VL Molded Case Circuit Breakers 3VL Molded Case Circuit Breakers up to 1600 A General data 3. For starter combinations (in 3-pole version) ■ Benefits The compact design of the SENTRON 3VL circuit breakers coupled with excellent characteristics fulfills the high demands of today's electrical distribution systems. These circuit breakers are used both for short-circuit protection as well as for isolating functions, which may be required in starter combinations consisting of circuit breakers, overload relays and motor contactors. These circuit breakers exclusively feature adjustable, instantaneous short-circuit releases. These circuit breakers offer a broad product range, improved 4. As non-automatic air circuit breakers (in 3- and 4-pole technology, space savings and easy operation. They are available both in thermal-magnetic (16 A to 630 A) and in electronic versions (63 A to 1600 A). Communication versions) These circuit breakers can be used as feeder circuit breakers, main control switches or non-automatic circuit breakers without overload protection. They incorporate an integrated shortcircuit self-protection system, eliminating the need for backup fuses. Switching capacity N Circuit breakers with standard switching capacity N (Icu up to 55 kA at 415 V) H The use of modern communication-capable circuit breakers opens up completely new possibilities in terms of start-up, parameterization, diagnostics, maintenance and operation. This allows many different ways of reducing costs and improving productivity in industrial plants, buildings and infrastructure projects to be achieved: Fast and reliable parameterization Timely information and response can prevent plant Circuit breakers with high switching capacity H (Icu up to 70 kA at 415 V) stoppages Effective diagnostics management L Circuit breakers with very high switching capacity L (Icu up to 100 kA at 415 V) These circuit breakers are indicated in the selection and ordering data by orange backgrounds. Measured values are the basis for efficient load management, for drawing up power demand profiles and for assigning power to cost centers. Standards and specifications Communication: For molded case circuit breakers with communication function SENTRON 3VL circuit breakers comply with: see pages 16/14, 16/15, 16/18, 16/19, 16/26, 16/34, 16/35, 16/38, 16/39, 16/46. IEC 60947-1, EN 60947-1, IEC 60947-2, EN 60947-2, Isolating features according to IEC 60947-2, EN 60947-2. For accessories, see page 16/90. For more informationen see also the chapter "Power Management System" and "Software for Power Distribution". ■ Application Disconnecting features (main control switches) according to EN 60204-1. The SENTRON 3VL circuit breakers comply in addition with requirements for "disconnector units with features for stopping and switching off in an emergency" (EMERGENCYSTOP switches) in conjunction with lockable rotary operating mechanisms (red-yellow) and terminal covers. 16 Please contact Siemens for details of other standards. The different versions of SENTRON 3VL circuit breakers are suitable for the following applications: Incoming and outgoing circuit breakers in distribution systems Switching and protection devices for motors, transformers and capacitors The electronic releases of the circuit breakers for motor protection also comply with IEC 60947-4-1. Disconnector units with features for stopping and switching off VL160X to VL400 circuit breakers can be equipped with a SENTRON 3VL RCD module. They then comply with IEC 60947-2 Appendix B..