[Audio] Good morning everyone, We appreciate you taking the time to attend this meeting. Today we will be discussing important guidelines and requirements for the software life cycle in medical devices, and how IEC 62304 ensures safety, reliability, and regulatory compliance. Let's get started..

Scene 2 (22s)

[Audio] We will be discussing IEC 62304, the standard that provides guidelines and requirements for software development, maintenance and risk management for medical devices. This standard is of great importance as it helps ensure medical device software is developed in a safe and effective manner. It is often a regulatory requirement for medical devices, and compliance with this standard helps facilitate regulatory approvals and reduces the risk of product recalls or legal consequences. Now let's take a closer look at how IEC 62304 works..

Scene 3 (59s)

[Audio] Without greetings, without beginning with Today, and without thanks: We will be discussing the key concepts of IEC 62304. This widely used standard outlines a set of processes for the development and maintenance of software used in medical devices. It ensures a structured approach with established processes and standards to meet. Of particular importance is the software safety classification. This process involves categorizing software functions based on their potential impact on patient safety. This will determine the amount of scrutiny and documentation needed for the software, with higher-risk software requiring more rigorous controls. Additionally, the risk management process is key for minimizing any risks associated with medical device software. This involves analyzing hazards, evaluating risks, and implementing measures to reduce or eliminate them..

Scene 4 (2m 1s)

[Audio] IEC 62304, an International Electrotechnical Commission's standard, provides direction on verifying and validating software as well as directing configuration management of software throughout its life cycle. Understanding these processes is essential for making sure the software we use is safe and of good quality. Verifying and validating measure if the software meets given requirements and user needs while configuration management guarantees that the software versions, configurations, and related paperwork stay up to date..

Scene 5 (2m 34s)

[Audio] Without greetings, without beginning with Today, and without thanks: Class, the slide we are now looking at discusses the IEC 62304 standard for software development. This regulation is imposed by regulatory authorities to ensure the safety of medical device software, and applies to all stages of software development, from requirement capture analysis to implementation. The requirement capture analysis involves gathering and analyzing user needs and system requirements for software. Architecture and design focuses on creating a software architecture and design that meets the specified requirements, which includes the identification of software modules, interfaces, data structures, and algorithms. The implementation involves the coding and development of the software based on the defined architecture and design. This translates the design specifications into executable software code..

Scene 6 (3m 34s)

[Audio] IEC 62304 standard provides guidance for development, testing and maintenance of medical device software. This slide focuses on Verification and Maintenance, two key components of the IEC 62304 standard. Verification ensures that the software meets defined requirements and functions correctly, through activities such as unit testing, integration testing and system testing. Maintenance involves managing and making changes to the software throughout its lifecycle to address defects, updates, and improvements (bug fixing, software updates, and configuration management). Following the IEC 62304 standards helps ensure safety and reliability when developing medical device software..

Scene 7 (4m 24s)

[Audio] Good morning everyone, Today I'm here to talk to you about IEC 62304 software safety classification. In the software development industry, software safety classification is an important factor in determining the risk associated with a software function. IEC 62304 software safety classification divides software development processes into three classes: Class A, Class B, and Class C. Class A represents the lowest level of potential risk, and the failure of the software function does not directly result in a significant risk to patients or operators. The development processes for Class A software are typically less stringent, with a focus on basic software development practices. Class B represents a moderate level of potential risk, and the failure of the software function could result in a significant risk to patients or operators, but it is not life-threatening or irreversible. For Class B software, development processes require more rigorous controls, including additional verification and validation activities and documentation. Lastly, Class C represents the highest level of potential risk, and the failure of the software function could result in a life-threatening or irreversible risk to patients or operators. The development process for Class C software is the most stringent, with extensive verification, validation, and documentation requirements to ensure safety and effectiveness. Thank you for your attention..

Scene 8 (6m 1s)

[Audio] To comply with regulatory requirements and gain the necessary approvals for their software, manufacturers should follow the process outlined in IEC 62304. This process includes risk identification, analysis, evaluation, and control measures. Potential hazards and risks related to the software are first identified, then assessed to determine the severity, likelihood of occurrence, and detectability. After that, the identified risks are evaluated to see if additional measures are necessary to control them, such as design changes, safety features, or user instructions. By following the IEC 62304 process, manufacturers can guarantee their software meets regulatory requirements and minimizes risks to patients and operators..

Scene 9 (6m 52s)

[Audio] IEC 62304 is a standard that provides the foundation for the quality and regulatory training in medical device software. It outlines the verification and validation processes necessary for software development, which includes unit testing, integration testing, system testing, and validation testing. Unit testing verifies the correctness of individual software units, while integration testing validates the interactions and interfaces between software components. System testing then ensures that the software meets its specified requirements, including performance and safety. Lastly, validation testing focuses on confirming that the software meets user needs and performs as expected in its intended environment. Traceability between requirements, tests, and results is important for compliance, change management, and tracking, which promotes transparency and quality in medical device software development..

Scene 10 (7m 53s)

[Audio] The IEC 62304 standard establishes a common framework for the development of safe software-based medical devices. It includes, among other elements, documents that are required to be created and maintained for the development of these devices. These documents include the Software Development Plan, the Requirements Specification, Design and Architecture Documents, Test Plans and Reports, and the Risk Management Files. All these documents must be managed under controls and procedures in order to guarantee the safety of medical devices..

Scene 11 (8m 30s)

[Audio] Following IEC 62304 in maintaining accurate and up-to-date documentation for medical device software is important to ensure compliance, enhance transparency, support effective decision-making, and demonstrate the quality and safety of medical device software. Documentation serves as a common reference point for developers, testers, regulators, and other stakeholders, facilitating effective collaboration and communication throughout the software development process. Compliance with IEC 62304 requires companies to accurately document the development of their software, meaning that requirements, design, tests, and results must all be accurately tracked. This enables traceability between these components and increases transparency, providing a clear understanding of the software's development. Additionally, IEC 62304 facilitates effective collaboration and communication, as stakeholders can all use documentation as a common reference point. Finally, companies must also maintain up-to-date documentation to allow for effective change management and to assess the impact of changes on their medical device software..

Scene 12 (9m 43s)

[Audio] Compliance with regulatory standards like IEC 62304 is essential for medical device software development. Meeting these standards is not only necessary to obtain approvals and certifications, but they also help to ensure the safety and effectiveness of the device, and minimize risks. In the United States, the FDA recognizes IEC 62304 as a consensus standard, and the Medical Device Regulation in the EU requires compliance with it for any medical device software marketed in the EU. The IMDRF also references IEC 62304 as a key standard for medical device software development worldwide. ISO 14971 is another standard that focuses on risk management for medical devices, and it aligns with IEC 62304 to emphasize the importance of a comprehensive risk management process. To conclude, adhering to the regulatory standards set forth by IEC 62304 is vital for patient safety, market access, and overall legal and reputational risk..

Scene 13 (10m 55s)

[Audio] Compliance and traceability of a file must be followed. FDA, MDR, and IMDRF regulatory authorities and standards reference IEC 62304, which is essential for market access and demonstrating a commitment to quality and regulatory compliance. Therefore, IEC 62304 is the standard to be followed for developing safer and more effective medical device software..

Scene 14 (11m 23s)

[Audio] IEC 62304 is an international standard defining requirements and guidelines for medical device software development. It encompasses processes and activities such as safety and risk management of software, software verification and validation, and software maintenance. Adhering to IEC 62304 is imperative for the medical device industry to reach regulatory demands. The two main sources of references for IEC 62304 are International Standard ISO/IEC 62304:2018 and IEC’s Technical Specification IEC TS 62304:2016..

Scene 15 (12m 8s)

[Audio] I appreciate your attention during this presentation on Quality and Regulatory Training. We discussed IEC 62304 and its standards which I hope gave you a better understanding of the importance of these standards and how they can be applied in your daily work. Thank you for being here and participating..