HTY - SRV 2230 Controller Without Corner Fill

Published on
Embed video
Share video
Ask about this video

Scene 1 (0s)

[Audio] We are here today to discuss the issue we have identified in our H-V-M lots of Stevie RAY-V 2550 30 millimeters drive. We have found that underfill was present in the P-M-I-C while the controller had no cornerfill. This has resulted in a 100% failure rate on H-V-M lots, with an estimated quantity of 542k affected. We have conducted a risk assessment and have determined that a rework plan and containment of the affected lot are necessary to address the issue. This containment action will involve Dell and other customers, and will involve sharing a rework plan and time to complete the necessary work on over 500k drives. We are also working to strategize communication with customers and obtain a waiver to accept the configuration with no cornerfill controller, supported by packrel data. This containment action will involve a total of approximately 155k in WIP. We understand the significant impact this issue has had on our business and are committed to resolving it as quickly and efficiently as possible. Thank you for your attention, and we will provide you with updates on our progress..